Description
MG1K5TL | MG3KTL | MG5KTL-2M | MG6KTL-2M | |
---|---|---|---|---|
Input (DC) | ||||
Max. DC input power (W) | 1700 | 3300 | 6000 | 6300 |
Max DC input voltage (V) | 400 | 450 | 600 | |
Starting voltage (V) / Min. operation voltage (V) | 80/60 | 120/100 | ||
MPPT range (V) | 80-410 | 120-450 | 125-550 | |
Quantity of MPPT / String per MPPT | 1/1 | 2/1 | ||
Max. DC current (A) per MPPT x Quantity of MPPT | 10x1 | 15x1 | 12x2 | 16x2 |
Output (AC) | ||||
Rated output power (W) | 1500 | 3000 | 5000 | 6000 |
Max. AC output current (A) | 6.5 | 13 | 22.7 | 26 |
Power factor | ≥ 0.99 (at rated power) | ≥ 0.99 (at rated power) | ||
THDi | < 3% (at rated power) | < 3% (at rated power) | ||
Nominal output voltage (V) / frequency (Hz) | 230, L+N+PE, 50/60 | 230, L+N+PE, 50/60 | ||
Efficiency | ||||
Max. efficiency | 97.20 % | 97.30 % | 97.40 % | 97.80 % |
Euro- efficiency | 96.10 % | 96.50 % | 96.80 % | |
MPPT efficiency | 99.90 % | |||
Protection | ||||
Protection | DC breaker, AC short-circuit protection, Over current protection, Over voltage protection, Isolation protection, RCD, Surge protection, Anti-island protection, Over-temperature protection, Ground fault monitoring, etc. | |||
General data | ||||
Display | LCD (standard) | |||
LCD language | English, Chinese, German, Dutch | |||
Communication interface | RS485 (standard); WiFi, Ethernet (optional) | |||
Cooling method | Natural cooling | |||
Protection degree | IP65 | |||
Night self consumption (W) | < 1 | |||
Topology | Transformerless | |||
Operating temperature range | -25℃ ~ +60℃ (derate after 45℃) | |||
Relative humidity | 4 ~ 100%, condensation | |||
Dimension (H x W x D mm) | 280x300x138 | 462x360x150 | ||
Weight (kg) | ≤ 9.5 | ≤ 18 | ||
Grid qualification | DIN VDE 0126-1-1:2013, VDE-AR-N 4105:2011, DIN VDE V 0124-100:2012, EN 50438:2013, G83-2 :2012, IEC 61727(IEC62116), AS/NZS 4777.2:2015, NB/T32004-2013, IEC 60068-2-1:2007, IEC 60068-2-2:2007, IEC 60068-2-14:2009, IEC 60068-2-30:2005, IEC 61683:1999, C10/11, TF3.2.1 |
|||
Safe certificates / EMC certificates | IEC 62109-1:2010, IEC 62109-2:2011, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011 | |||
Factory warranty (years) | 5(standard)/10(optional) |